Pacific Gas Technology specializes in the physical and chemical testing of natural gas, natural gas liquids and LPG, providing accurate and timely data to the gas producing and gas processing industry. Our services include Total flow meter calibration to the petroleum industry.

Gas Analysis By Chromatography


ServiceType
Natural Gas
  • ASTM D1945
    • Fixed Gases: H2, N2, O2, CO2, CO
    • Light Hydrocarbons: C1-C6+ iso & n, butanes and pentanes distinguished
  • ASTM D3588
    • Heat Value
    • Relative Density and Compressibility Factor
  • GPA 2146-96
    • G/MCF
H2S in Gaseous FuelASTM D6228 (GC/FPD)
Royalty Gas
  • Hydrocarbons C1-C6+ (FID)
  • Inorganics: H2, N2, O2, CO2, CO (TCD)
  • Specific Gravity
  • BTU
  • G/MCF
Natural Gasoline CondensatesHydrocarbons C1-C6+
Liquefied Petroleum Gas-LPGHydrocarbons C1-C6+
Hydrocarbon AnalysisChromatography

Other Gas Testing


ServiceType
Total Sulfur Analysis(ASTM D-3246)

Source Test Method Analysis


ServiceType
Hydocarbons in AirEPA M18
Fixed Gases in AirEPA 3C
Aqueous Sulfuric Acid Air SampleEPA Method 6 & 8
Hyrodrogen SulfideEPA Method 11
Condensable Particlate MatterEPA Method 5-202
AmmoniaBAAQMD ST1B

Other Services


Service
Tedlar Bag
Sample Disposal

Field Services


ServiceType
Field Testing

Our field technicians have many years experience in service to the oil and gas industry. We maintain the sampling equipment and containers necessary for procuring samples. We are available to collect your samples and route them to a carefully selected testing laboratory.

  • Sampling, per hour (two hour minimum)
  • Mileage: special quote when applies
Hydrogen Sulfide(Detector Tube, ASTM D-4810)
CO2 Reading Can be performed on the field or in the lab
O2 Reading Can be performed on the field or in the lab
Dew Point Moisture Content, performed on the field
Calibration Services

Total Flow Calibration & Repairs

Total flow calibrations will include a natural gas analysis, astm d1945, performed in pgt’s in-house laboratory. We also provide a 3 day turnaround time on our standard gas analysis.

Terms and Conditions of Service


ConditionDetails
Laboratory Services

We reserve the right to charge an additional fee for samples requiring more than normal preparation time.

Overtime

Overtime charges may apply

Premium Time

48-72 hour turn around, surcharge

24 hour service, when available

Insurance


Pacific Gas Technology carries Contractor’s public liability and property damage insurance, as well as public liability and property damage insurance on vehicles and equipment. Certificates of Insurance furnished on request.

About Us

Request a quote



  • Office Hours

    Monday thru Friday:
    7am–4pm

  • Location

    4100 Burr Street
    Bakersfield, CA
    93308

  • Email & Phone

    pgtech@pacificgastech.com
    (661) 324-1317
    Fax: (661) 347-3310